May 16, 2019

How does concrete block insulation work

Leave a message

A new type of concrete block insulation work was successfully developed by Unik Machinery Ltd, The "insulation block" mainly uses burnt ash, power plant water slag, blast furnace hollow slag as the main raw material, adding expansion agent and binder, produces by eps concrete block machine and naturally dried.The outer side of the brick body is fixed with a foam layer through a first adhesive layer, and the outer side surface of the foam layer is fixed with a decorative surface layer through a second adhesive layer, and the first adhesive layer and the second adhesive layer are respectively built in There is a layer of reticular fibers. The utility model can not only effectively block the heat transfer outside the room, but also effectively maintain the indoor temperature and reduce the emission and loss rate of the indoor temperature. The utility model has the advantages of novel structure, strong heat insulation performance and good heat preservation effect.

Through the adjustment of the density, variety and thickness of the outer thermal insulation layer and the thermal insulation core material, the heat transfer coefficient of the new composite self-insulating block of 240 mm thickness is set between 0.55 W/m2·K and 0.40 W/m2·K; 290 mm The heat transfer coefficient of the thick new composite self-insulating block can be set between 0.35 W/m2·K and 0.15 W/m2·K.

Under the premise of not changing the production process, equipment and molds, it is of great significance to realize the adjustment of thermal insulation performance and strength, which is of great significance to the expansion of the market for production enterprises: to meet the requirements of various buildings for energy-saving indicators and strength indicators, and to expand the sales market. For example, the 65% energy saving index refers to the average heat transfer coefficient of the external wall of a building including doors and windows, beams and columns, etc., and does not refer only to the wall. Most of the insulation of beams and columns is based on the indoor dew point temperature; when the window and wall of the building is larger than the large coefficient of heterogeneity, it should be balanced by improving the insulation performance of the wall. In different buildings in the same area, the walls of different walls of the same building have different insulation performance requirements. For example, when energy saving is 65%, the heat transfer coefficient of the outer wall is required to be ≤0.6 W/m2·K for buildings with more than six floors, and the heat transfer coefficient of the outer wall for buildings below six floors is ≤0.45 W/m2·K.

insulation block wall

Best Regards

Jonathan Yan (exported manager)

UNIK Machinery Limited

Mobile: (86)-18659803696
Whatsapp:+86-18659803696
Tel:    (86)-595-28085862
Fax:   (86)-595-28085861
E-mail:
Jonathan@unikmachinery.com 
Website:
www.unikblockmachine.com 

 

Send Inquiry